Scope and accuracy
Every calculator output on this site is a preliminary, AACE Class 5 order-of-magnitude estimate (typical accuracy −20% to −50% low, +30% to +100% high). It is meant to rank options and size a budget conversation. It is not a design, a quote or a performance guarantee, and it must be validated with an ion chromatography report, saturation modeling and treatability testing.
Mass balance
Stage ceilings: RO 70,000 mg/L; OARO 135,000 mg/L; MVR 245,000 mg/L; crystallizer to a cake of 90% solids by weight. In hybrid mode RO is used when feed TDS is below 70,000 mg/L and OARO when it is below 100,000 mg/L for thermal endpoints (below 135,000 mg/L for the membrane endpoint). Crystallizer evaporation uses an approximate brine density of 1,000 + 0.7 × TDS/1000 kg/m³ and leaves cake moisture of one-ninth of the solids mass.
Specific energy by stage
| Stage | SEC used | Basis | Published range |
|---|---|---|---|
| RO | 3.8 kWh/m³ | per m³ permeate | 2.5–5.0 |
| OARO | 13.0 kWh/m³ | per m³ permeate | 6–20 |
| MVR brine concentrator | 52 kWh/m³ | per m³ evaporated | 40–80+ |
| Crystallizer | 78 kWh/m³ | per m³ evaporated | 60–110+ |
| Conditioning factor | +15% | high silica / CaSO₄ and FGD profiles | – |
CAPEX curve (mass balance modeler)
The curve reproduces published installed-cost bands: about $1.8M at 20 GPM, $7.7M at 150 GPM and $30M at 1,000 GPM for full ZLD.
Operating cost
- Electricity = Σ stage kWh/day × operating days × $/kWh.
- Pretreatment and antiscalant chemicals per m³ feed: NaCl $0.45, lithium $1.10, high silica $1.40, FGD $1.80.
- Maintenance and membrane replacement: 3% of mid CAPEX per year for membrane-only trains, 4% when thermal stages are present.
- Residuals: MLD concentrate × your liquid disposal rate; ZLD cake tonnes × your tipping fee.
- Levelized operating cost = annual OPEX ÷ annual feed volume.
Hauling vs. evaporator calculator
Hauling and residual disposal escalate at the user's rate; utilities and maintenance at 2.5% per year. Cash flows are undiscounted. Tanker loads assume 5,000-gallon vacuum trucks.
Metallurgy screening
Alloy suggestions use the temperature and chloride limits listed in the metallurgy matrix, with stage temperatures assumed at ambient to 45°C for membranes, about 105°C for MVR and about 120°C for crystallizers. Chloride is estimated as 55% of TDS for NaCl-type brines.
Sources
- US Bureau of Reclamation, Desalination & Water Purification Research
- Santa Ana Watershed Project Authority, Inland Empire Brine Line
- Orange County Sanitation District
- US EPA Underground Injection Control program (40 CFR 144/146)
- US EPA Resource Conservation and Recovery Act program
- US EIA Electric Power Monthly
- US EIA Short-Term Energy Outlook
- Environmental Research & Education Foundation (EREF), MSW tipping fee analysis
- AACE International Recommended Practice 18R-97 (cost estimate classification)
- eCFR: 40 CFR Part 423, Steam Electric Power Generating Point Source Category
- US EPA Steam Electric Power Generating Effluent Guidelines
Industry ranges for hauling tiers, ZLD operating cost and technology SEC are compiled from vendor literature, published case studies and technical papers on high-recovery desalination and ZLD, and are reviewed as new data appears.